banner

All Weather GPU

1.Output: 115V/200V 400Hz, three‑phase, 60kVA continuous
2.Technology: Solid‑state IGBT converter with sealed IP56 enclosure
3.Input: 380‑480V three‑phase, 50/60Hz ±15%
4.Key feature: Built‑in heater and filter system for -30°C to +55°C operation
5.Applications: Arctic airfields, desert bases, offshore helidecks, exposed mountain ramps
6.Compliance: MIL‑STD‑704F, MIL‑STD‑810 (environmental)
7.Applications: aviation R&D and military equipment
8.Brand: ACSOON (support OEM)
9.Features: multiple history events memorized in record.
Send Inquiry Download
  • Product Description

All Weather GPU | 60kVA 400Hz Ground Power for Extreme Cold, Heat & Sand

Reliable Aircraft Ground Power All Weather GPU
For Arctic Cold, Desert Heat & Offshore Operations

✔ -20°C to +55°C Operating Range
✔ IP56 Sealed Enclosure
✔ MIL-STD-704F Compliant
✔ THD <2%
✔ No External Shelter Required

Standard GPUs have limits. Below -20°C, the electronics get sluggish. Above 50°C, they overheat. In a sandstorm, filters clog. The All Weather GPU was built for places where normal equipment fails.It has a sealed IP56 cabinet – no sand getting in. A thermostatically controlled heater keeps internals above freezing in Arctic conditions. Oversized fans and a bypass filter handle 55°C desert heat. The same clean 400Hz power, just in a box that doesn't care where you put it.We ship these to military bases in Alaska, mining sites in the Sahara, and offshore platforms in the North Sea. They run. No special shelters required.

All Weather GPU

product-1-1

Datasheet

ParameterSpecification
Model SeriesACSOON GPU400 Series
Input3‑phase 380V/400V/415V/440V/480V ±15%, 50/60Hz
Output115V/200V 400Hz ±0.01%, 60kVA continuous
Voltage THD<2% at linear load
Voltage Regulation±1% FS
Operating Temp-30°C to +55°C (ambient)
EnclosureIP56, steel with gasketed doors
Heater500W, automatic, 5°C setpoint
CoolingDual high‑temp fans, washable filter
Overload150% for 60 seconds
ProtectionsOver‑voltage, over‑current, short circuit, over‑temp
ComplianceMIL‑STD‑704F, MIL‑STD‑810​​​​​​​

If you need it,Contact us at Email: acpower@acsoonpower.com

Feature

Main Feature
01

All Weather GPU Main Features

Thermostatic heater – 500W, kicks in at 5°C. Keeps electronics at 10‑20°C internally.

Oversized fans with filter – Moves more air than standard unit. Filter catches sand.

Stainless steel hardware – All external fasteners and latches are stainless. No rust.

Drain valve – In case condensation builds up, open the valve at the bottom.

02

Why Choose ACSOON All Weather GPU?

Works anywhere – From -30°C to +55°C ambient. No derating, no shutdowns.

Sand and salt proof – IP56 rated. Dust‑tight, protected against powerful water jets.

No extra shelter needed – Just set it on the ramp. It's its own weatherproof box.

Same reliable power – 60kVA, 400Hz, THD under 2%. Same as our standard GPU.

ACSOON All Weather GPU
 Application Areas
03

All Weather GPU Application Areas

Arctic airfields – Heated enclosure. No pre‑heating required before use.

Desert military bases – Sandstorm? Close the door. Unit keeps running.

Offshore helidecks – Salt spray resistant. Sealed connectors and stainless hardware.

High mountain airports – Thin air, wide temperature swings. This unit handles both.

04

Quality Control

Cold chamber test – Every unit runs at -30°C for 2 hours. Heater must hold internal temp above 0°C.

Hot chamber test – 55°C for 4 hours at full load. No over‑temp alarms.

IP56 water test – High‑pressure spray from all directions for 10 minutes. No water inside.

Sand test – Blown sand against the intake for 30 minutes. Filter catches it.

Quality Control

 

R&D Results
05

R&D Results

Heater placement – First unit had heater near the top. Heat rose, bottom stayed cold. Moved to the bottom. Much better.

Filter design – Original filter clogged fast in heavy dust. Switched to a cyclonic pre‑filter. Lasts 10x longer.

Door seals – Used automotive‑grade bulb seals. Stays flexible down to -40°C. No cracking.

Customer feedback – An Arctic operator wanted a way to check internal temp without opening the door. Added a display on the outside.

06

Packaging and Transportation

Shipped from Xi'an – On a heavy skid, bolted down, covered with a breathable waterproof cover.

No crate needed for domestic – The unit itself is the crate. For export, add a wooden crate.

Documentation – Laminated cold weather quick start, full manual on USB.

Extra filter – One spare filter included.

Packaging and Shipping
After‑Sales Service
07

After‑Sales Service

1‑year warranty – Covers electronics, heater, fans. Filters are consumable.

Spare parts (heater element, fans, control board) kept in Xi'an.

Email support – We answer within one business day. Include temperature readings.

08

Qualification Certification

CE – LVD and EMC.

MIL‑STD‑810 – Environmental test report available.

ISO 9001:2015 – Our Xi'an facility.

Qualification Certification

FAQ

Q1: Do I need a separate power source for the heater?
A: No. The heater runs off the input power when the unit is plugged in. No extra connection.

Q2: Can I use this in a cold climate without the heater?
A: Not recommended. Electrolytic capacitors lose capacitance below -10°C. The heater keeps them warm. Without it, the unit may fail to start.

Q3: Is the filter washable?
A: The primary foam filter is washable. The secondary paper filter is not – replace it. We include one spare.

Q4: What's the difference between IP56 and IP54?
A: IP54 is dust‑protected and splashing water. IP56 is dust‑tight and high‑pressure water jets (hose down). This unit can be pressure‑washed from a distance.

Q5: Lead time from Xi'an?
A: 5‑6 weeks. The heater and sealed enclosure are built to order.

Contact Us


For technical specifications or global solutions for the All Weather GPU: acpower@acsoonpower.com, or submit your requirements using the form at the bottom of our website.

REQUEST QUOTE

Online Message