banner

Low Maintenance Ground Power Unit

1.Power Output: 90kVA 400Hz AC (115V/200V, 3-phase)
2.Technology: Maintenance-optimized solid-state design
3.Input: 3-phase 400VAC ±15%, 50/60Hz auto-sensing
4.Maintenance: Extended service intervals design
5.Key Applications: Remote airports, cost-sensitive operations, minimal maintenance facilities
6.Key Features: Extended service life; reduced maintenance; reliable operation; cost-effective
7.Brand: ACSOON (low maintenance configurations available).
Send Inquiry Download
  • Product Description
 

Low Maintenance Ground Power Unit | Reduced Maintenance Aircraft Power​​​​​​​

 

XI'AN JERRYSTAR INSTRUMENT CO., LTD manufactures efficient low maintenance ground power units for operations where minimizing maintenance requirements is essential. Our systems are engineered with extended service intervals and durable components, providing reliable 400Hz power while significantly reducing maintenance costs and downtime for remote airports and cost-conscious operations.

Low Maintenance Ground Power Unit
Low Maintenance Ground Power Unit
Low Maintenance Ground Power Unit
 

Technical Specifications

 
FeatureSpecification
Capacity (Three Phase Output)30kVA, 45kVA, 60kVA, 90kVA, 100kVA, 120kVA, 150kVA, 180kVA
Input Voltage (Three Phase)200Vac, 208Vac, 380Vac, 400Vac, 415Vac, 440VAC (L-L) ±20%
Input Frequency40 - 70HZ
Output Voltage (Three Phase)200VAC / 208VAC rated, 0-260Vac, 0-520VAC (L-L)
Output Frequency400HZ rated, 300HZ - 500HZ adjustable
Voltage Regulation±1%
Frequency Stability≤0.1%
VTHD<2%
Power Factor≥0.8 (Standard), ≥0.9 (12 Pulse Optional)
Overall Efficiency≥85%
Overload Capacity125% for 10 mins, 150% for 60s, 200% for 30s, 400% for 1s
MTBF30,000 hours
Noise Level<65dB at 1 meter
Low Maintenance Ground Power Unit
 
 

Low Maintenance Ground Power Unit Main Features

  • Auto voltage compensation system, ideal voltage at aircraft connector
  • Self diagnose system which would show error code on digital display
  • 10 events memory stores
  • Pure sine wave, sinusoidal output
  • Completely protection and alarm for over voltage, over current and overheating, etc
  • Eco-friendly, lower power consumption with high efficiency
  • With 28VDC military interlock
Low Maintenance Ground Power Unit

Why Choose ACSOON Low Maintenance Ground Power Units?

 

ACSOON delivers cost-effective reliability through reduced maintenance:

Extended Intervals: Longer periods between required maintenance

Reduced Costs: Lower overall maintenance expenditures

Reliable Operation: Consistent performance with minimal servicing

Durable Components: Long-lasting parts selection

Easy Servicing: Simplified maintenance procedures

Application Areas

 

Our low maintenance ground power units are essential for:

Remote Airports: Limited maintenance capabilities

Cost-Sensitive Operations: Budget-conscious facilities

Minimal Staff Sites: Limited technical personnel

Regional Airports: Reduced maintenance requirements

Emergency Fields: Low maintenance priority locations

Temporary Setups: Short-term low-maintenance needs

Basic Operations: Simple maintenance capability sites

Budget Facilities: Cost-effective operation requirements

Application Areas

Our Services

Quality Assurance
01

Quality Assurance

Each low maintenance ground power unit undergoes thorough testing:

  • Extended operation testing
  • Component lifespan validation
  • Maintenance interval verification
  • Reliability testing
  • Performance certification
02

Technical Features

Our low maintenance ground power unit incorporates:

  • Durable component selection

  • Extended service design

  • Simplified maintenance access

  • Robust construction

  • Long-life cooling system

Technical Features
Packaging And Delivery
03

Packaging and Delivery

We ensure practical packaging:

  • Protective packaging materials

  • Clear maintenance documentation

  • Worldwide shipping services

  • Installation guidance

04

After-Sales Service

Low maintenance support includes:

  • Extended service intervals

  • Remote support capability

  • Parts availability

  • Maintenance guidance

  • Training programs

After-Sales Service

Certifications

CE Certification
CE Certification

FAQ

Q1: What are the main advantages of low maintenance ground power units?
A: Reduced maintenance frequency, lower operating costs, and reliable performance with minimal servicing.
Q2: How are maintenance intervals extended?
A: Through durable component selection and optimized system design.
Q3: What cost savings can be expected?
A: Significant reduction in maintenance labor and parts replacement costs.
Q4: How reliable is the system with less maintenance?
A: Designed for reliable operation with extended service intervals.
Q5: What types of facilities benefit most?
A: Remote locations and cost-sensitive operations with limited maintenance capabilities.

Contact Information

For technical specifications or low maintenance solutions: acpower@acsoonpower.com ,or submit your requirements using the form at the bottom of our website.​​​​​​​

Online Message
Learn about our latest products through SMS or email